Published: CABEQ 18 (1) (2004) 73–76
       Paper type: Original Scientific Paper 
     
I. Hace, J. Golob and M. Krajnc
Abstract
      Attenuated total reflection infrared spectroscopy (ATR-FTIR) was used to measure
diffusion of diallyl terephthalate monomer (DAT) into a polyDAT film. The assembly,
consisting of an ATR crystal, polymer film and a monomer, was heated to a desirable
interdiffusion temperature, the spectra thus obtained were deconvoluted and the diffusion coefficient of DAT monomer into polymer was calculated by least square regression technique at various temperatures from 21 °C to 50 °C and, various film thicknesses from 60 μm to 180 μm.
    

This work is licensed under a Creative Commons Attribution 4.0 International License
    
Keywords
      diffusion, diffusion coefficient, Fourier transform infrared attenuated total reflectance (FTIR-ATR), diallyl phthalate, diallyl terephthalate